<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15305</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Unload cups rotated, can't move unload carriage
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Select the RESUME button on the workstation dialog box. If this fails to correct
the problem, check that nothing is obstructing the unload table traveller to
prevent it from moving back into the un-rotated position. If everything looks
normal, then Creo Service should be called.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
This error is reported when the recorder needs to move the unload table
stepper motor and the unload traveller is in the ROTATED position. The stepper
motor will NOT move when the traveller is rotated (unless the unload traveller
rotate sensor is disabled).
</text></DescriptionText>
<DescriptionText><text>
The unload table rotator sensors indicate that the rotator is NOT in the normal
"un-rotated" position required for moving the stepper motor.
</text></DescriptionText>
<DescriptionText><text>
It may be useful to set the 'verbose alcmd' and 'verbose alconv' parameters to 1
in order to obtain further diagnostic information.
</text></DescriptionText>
<DescriptionText><text>
This error is most likely caused either by someone putting the unload cups in
the ROTATED position using the diagnostic commands or by a problem with the
sensors.
</text></DescriptionText>
<DescriptionText><text>
The sensor status may be checked by using the TABLE command. The sensor status
should read TRUE if the sensors are activated.
</text></DescriptionText>
<DescriptionText><text>
Typing "ALE" will display the system air pressure.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The rotator may be obstructed by something.
</Cause>
<Cause>
The rotator magnetic sensors may not be adjusted correctly.
</Cause>
<Cause>
The magnetic sensors may have been damaged.
</Cause>
<Cause>
The aldly ucr timeout value may be set too short.
</Cause>
<Cause>
The wiring to the air valve solenoid may be disconnected or damaged.
</Cause>
<Cause>
The wiring to the magnetic sensors may be disconnected or damaged.
</Cause>
<Cause>
The pneumatic speed controls may be mis-adjusted.
</Cause>
<Cause>
The pneumatic system may be damaged.
</Cause>
<Cause>
The air supply may be low or turned off.
</Cause>
<Cause>
If the rotator is functioning correctly but the sensors are not working, then
the unload traveller rotate sensors may be temporarily masked off by setting al
urs to 0. Masking off these sensors will get rid of the error message but will
cause the machine to run significantly slower than it used to.
</Cause>
<Cause>
WARNING:  Masking off sensors disables proper error checking!
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/table.xml</LinkAddress><LinkTitle>Command: table</LinkTitle></Link>
<Link><LinkAddress>../commands/resume.xml</LinkAddress><LinkTitle>Command: resume</LinkTitle></Link>
<Link><LinkAddress>../commands/ale.xml</LinkAddress><LinkTitle>Command: ale</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cal_urs.xml</LinkAddress><LinkTitle>NVS: al urs</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldly_cal_ucr.xml</LinkAddress><LinkTitle>NVS: aldly ucr</LinkTitle></Link>
<Link><LinkAddress>../nvs/verbose_cfg_alcmd.xml</LinkAddress><LinkTitle>NVS: verbose alcmd</LinkTitle></Link>
<Link><LinkAddress>../nvs/verbose_cfg_alconv.xml</LinkAddress><LinkTitle>NVS: verbose alconv</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:00 2008 PST
</Updated>
<Links>
</Links>
</Error>